Advertisement · 728 × 90
#
Hashtag
#IABP
Advertisement · 728 × 90

#IABP

3 0 1 0
Post image

IABP support in MI complicated by ventricular septal rupture—clinical insights into a high-risk scenario.
doi.org/10.15212/CVI...
#MyocardialInfarction #IABP #VentricularSeptalRupture #Cardiology

0 0 0 0
Video

til that the little bounce off the ground after an air combo can make otg 2k whiff #IABP

4 1 1 0
Post image

🔋Safety Corrective Action for CS100 & CS300 IABP
This update clarifies battery specs — not a recall or device failure.
Min battery runtime=135min-120 bpm
🔄 Battery management update: Replace every 3 years
👉Learn more: youtu.be/poyvCspcKnA
#iabp

1 0 0 0
Video

🩺 #IABP Best Responders – Patient Selection Matters

👉Learn more in the full video: INTRAAORTIC BALLOON PUMP: WHO ARE THE BEST RESPONDERS?
youtu.be/jeUAYcgVhnE

1 0 0 0
Video

• IABP CONTRAINDICATIONS

❌ Aortic Regurgitation
❌ Aortic Dissection
❌ Aortic Aneurysm
❌ Severe PAD

👉 Learn more: IABP GUIDE 004
youtu.be/XW3tQxjCQDk

#globalmcscommunity #IABP

0 0 0 0
Post image

· ⚠️CARDIOSAVE PROPER CONSOLE DOCKING
CardioSave Hybrid must be properly docked in the cart to operate on AC and charge batteries.
New visual alerts implemented to prevent this issue...
-> Learn more: CARDIOSAVE IABP, PROPERLY CONSOLE DOCKING.
youtu.be/TqzeKiZ7ZEE
#iabp

0 0 0 0
Post image

Fu Wai Hospital's Dr. Zheng Xiaohui team successfully took on a CHIP ultra-high-risk PCI challenge with IABP support. Patient: elderly, severe heart failure, CABG history. We used precise DCB technology to reopen the crucial vessel.#CHIP #PCI #IABP #CardiovascularSurgery #FuWaiHospital

1 0 0 0
INTRA-AORTIC BALLOON PUMP (IABP): INDICATIONS, CONTRAINDICATIONS & OFF-LABEL USE (IABP GUIDE 004)
INTRA-AORTIC BALLOON PUMP (IABP): INDICATIONS, CONTRAINDICATIONS & OFF-LABEL USE (IABP GUIDE 004) YouTube video by Cicudevices

· IABP GUIDE 004: INDICATIONS, CONTRAINDICATIONS & OFF-LABEL USE
We recently developed our perspective on the role of the IABP🫀, focusing current indications, contraindications, and off-label uses.

👉Learn more: youtu.be/XW3tQxjCQDk
#iabp

0 0 0 0
Post image

Clarity is pround to support World Sight Day 2025! We call on everyone to #LoveYourEyes by prioritising your eye health and calling for eye checks to be made available to all.
#WorldSightDay2025 #LoveYourEyes #IABP

0 0 0 0
Post image

Clarity is proud to support World Sight Day 2025! #LoveYourEyes by prioritising your eye health and calling for eye checks to be made available to all.
#WorldSightDay2025 #LoveYourEyes #IABP

0 0 0 0
Post image

Clarity is proud to support World Sight Day 2025! We call on everyone to #LoveYourEyes by prioritising your eye health and calling for eye checks to be made available to all.
#WorldSightDay2025 #LoveYourEyes #IABP

0 0 0 0
Post image

🚨CARDIOSAVE IABP OVERTEMPERATURE RISK
Aug 2025
Getinge reported over-temperature events in Cardiosave systems.
If internal temps exceed 80°C, console enters standby, interrupting counterpulsation therapy…1/2
#IABP

0 0 1 0
Post image

• CARDIOSAVE IABP CONTROLER SAFETY ALERT
Aug 2025
Fluid ingress risk

Cardiosave Hybrid & Rescue #IABP consoles, face a risk: fluid ingress. Even small spills of saline can damage electronics, causing sudden device shutdown and interruption of counterpulsation…1/2

0 0 1 0
The second slide from the August 2025 issue of Journal Watch, titled "Early Intra-Aortic Balloon Support for Heart Failure-Related Cardiogenic Shock: A Randomized Clinical Trial." For a more screenreader friendly version, the full issue PDF is at https://www.ishlt.org/docs/default-source/journal-watch/2025-08-journalwatch-cardiology.pdf.

The second slide from the August 2025 issue of Journal Watch, titled "Early Intra-Aortic Balloon Support for Heart Failure-Related Cardiogenic Shock: A Randomized Clinical Trial." For a more screenreader friendly version, the full issue PDF is at https://www.ishlt.org/docs/default-source/journal-watch/2025-08-journalwatch-cardiology.pdf.

In the second study for #ISHLTJournalWatch last month, Max Berrill reviews a randomized #clinicaltrial from JACC about early #IABP for #HF-related #CardiogenicShock.

#CardioSky #TransplantSky

0 0 1 0
Post image

CICU night shift.
Patient on #IABP support.
Then… the console alarm starts screaming.
🚨 What to do?
1. Change helium tubing
2. Ignore alarm
3. Standby and removal
4. Check for kinking

#iabp

0 0 0 0
Video

• AC3 Range #iabp Driving Unit
FDA clearance April 2025.
Designed by Teleflex, created to simplify inter-hospital transfers.
To achieve this, it integrates smart design, a dedicated helium cylinder, and reliable batteries.
👉Learn more: AC3 RANGE
youtu.be/S-9C00vQoP8

1 0 0 0
Post image

CICU night shift.
Patient on #IABP support.
Then… the console alarm starts screaming.
🚨 What to do?
👉Learn more: IABP MEMBRANE RUPTURE RISK
youtu.be/lZ2idnU9-yA

1 0 0 0
Video

Did you know who first came up with the idea of DIASTOLIC AUGMENTATION?
Who coined the term CONUTERPULSATION?
And who implanted the very FIRST IN HUMAN IABP?
👉Learn more: youtu.be/DjX7wA8vw94
#iabp

1 0 0 0
TELEFLEX AC3 RANGE IABP CONSOLE OVERVIEW: HEMODYNAMIC SUPPORT ON THE MOVE. #iabp
TELEFLEX AC3 RANGE IABP CONSOLE OVERVIEW: HEMODYNAMIC SUPPORT ON THE MOVE. #iabp YouTube video by Cicudevices

· AC3 RANGE IABP CONSOLE
Available in US since May 2025, it is designed for use in ambulances, helicopters, and fixed-wing aircraft, ensuring patients receive uninterrupted hemodynamic support during transfers.
👉Learn more: youtu.be/S-9C00vQoP8
#iabp

0 0 0 0
Preview
Association of prehospital invasive blood pressure measurement and treatment times of intubated patients with suspected stroke – a retrospective study - Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine Background Invasive blood pressure measurement is commonly used in in-hospital patients with stroke requiring general anesthesia, but is much less established in the prehospital setting. While it…

Does #prehospital #invasive blood pressure measurement delay imaging & treatment times?

Prehospital #IABP monitoring did not delay time from on-scene arrival to the first imaging among patients with suspected #stroke who underwent #PHEA

1 0 0 0
Early Intra-Aortic Balloon Support for Heart Failure-Related Cardiogenic Shock: A Randomized Clinical Trial

In the Altshock-2 randomized trial, routine early #IABP plus standard care, compared with standard care, did not significantly improve survival or successful bridging to heart replacement therapies in patients with heart failure–cardiogenic shock www.jacc.org/doi/10.1016/...

2 3 1 0
Video

· FIBEROPTIC PRESSURE SENSORS FOR MEDICAL USE
Cardiovasc devices like #IABP or #Impella use a sensor based on Fabry-Pérot interferometer. Light beam reflected on 2 parallel memb. First memb partially reflects light, second fully reflects it.
👉Learn more: youtu.be/dcTXjDE3A2c?...

1 0 0 0
Post image Post image Post image

Must-read review on mechanical circulatory support for complex, high-risk percutaneous coronary intervention by Ferro et al in the latest issue of #EuroIntervention eurointervention.pcronline.com/article/mech... #IABP #Impella

2 0 0 0
Video

· IABP PHYSICS
Modern IABP drive consoles use a scroll compressor. It offers several advantages: efficiency, reduced noise and vibration, lower mechanical failures, and smaller size.
👉Full video: youtu.be/IDfj-mMcw8o?si…
#IABP

1 0 0 0

imaging in #MCS #tMCS in cardiogenic shock, ultrasound etc

, #IABP, #ECMO #IMPELLA etc,

#pocusky #cardiosky #cccsky
academic.oup.com/ehjcimaging/...

3 1 0 0
Preview
Imaging in acute percutaneous mechanical circulatory support in adults: a clinical consensus statement of the Association for Acute CardioVascular Care (ACVC) of the ESC, the European Association of C... Abstract. The use of temporary mechanical circulatory support (tMCS) in cardiogenic shock patients has increased during the last decades with most manageme

using #pocus #ultrasound for cardiogenic shock mechanical circulatory support #iabp #impella #ecmo #emimcc #cccsky #cardiosky
academic.oup.com/ehjcimaging/...

10 3 0 0
Post image

it is indeed variable. does this article help? #iabp LVEF cardiac output
#emimcc #critcaresky #cardiosky

cardiothoracicsurgery.biomedcentral.com/articles/10....

2 0 1 0
Non-invasive or arterial pressure monitoring in PHEM? This blog post reviews a study comparing non-invasive blo...

Great paper showing that non invasive BP measurement is unreliable in a PHEM case mix. #IABP better and feasible in prehospital care #foamed www.stemlynsblog.org/non-invasive-or-arterial...

0 0 0 0

#foamcc #foamed #meded #MedTwitter #Medstudent #hemodynamics #IABP

0 0 0 0